Sustainable Graphite Solutions for Low-Carbon Foundry Operations.
| Technical indicators | ||||||||||||
| 项目 Item |
单位 Unit |
普通功率RP | 普通高密功率HD | 高功率HP | 超高功率UHP | |||||||
| ①250-400 | φ450-600 | φ250-400 | ①450-600 | ①250-400 | φ450-600 | ①300-400 | ①450-500 | φ550-650 | Φ700-800 | |||
| 电阻率(不大于) Resistivity Max |
电 极 Electrode |
μΩm | 9.0 | 9.0 | 7.0 | 7.0 | 6.5 | 6.5 | 6.2 | 6.2 | 6.0 | 5.8 |
| 接 头 Nipple |
8.0 | 8.0 | 6.3 | 6.3 | 5.5 | 5.5 | 5.0 | 5.0 | 4.2 | 4.0 | ||
| 抗折强度(不小于) Flexural Strength Min |
电 极 Electrode |
Mpa | 8.0 | 7.0 | 10.0 | 9.0 | 10.5 | 10.0 | 10.5 | 10.5 | 11.0 | 11.0 |
| 接 头 Nipple |
15.0 | 15.0 | 17.0 | 17.0 | 18.0 | 19.0 | 20.0 | 20.0 | 22.0 | 23.0 | ||
| 弹性模量(不大于) Elastic Modulus Max |
电 极 Electrode |
Gpa | 9.3 | 9.3 | 12.0 | 12.0 | 14.0 | 14.0 | 14.0 | 14.0 | 14.0 | 14.0 |
| 接 头 Nipple |
14.0 | 14.0 | 16.0 | 16.0 | 16.0 | 16.0 | 20.0 | 20.0 | 22.0 | 22.0 | ||
| 体积密度(不小于) Bulk Density Min |
电极 Electrode |
g/cm³ | 1.54 | 1.54 | 1.64 | 1.64 | 1.65 | 1.65 | 1.67 | 1.66 | 1.66 | 1.68 |
| 接 头 Nipple |
1.72 | 1.72 | 1.74 | 1.74 | 1.74 | 1.74 | 1.75 | 1.76 | 1.78 | 1.78 | ||
| 热膨胀系数(不大于) C.T. E (100-600℃)Max |
电极 Electrode |
10-6/℃ | 2.9 | 2.9 | 2.6 | 2.6 | 2.4 | 2.4 | 1.5 | 1.5 | 1.5 | 1.5 |
| 接 头 Nipple |
2.7 | 2.7 | 2.3 | 2.3 | 2.0 | 2.0 | 1.4 | 1.4 | 1.3 | 1.3 | ||
| 灰分(不大于) Ash Max |
电极 接 头 |
% | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
| 公称直径 Nominal Diameter |
允许电流负荷(A) | |||
| Permissible Current Load | ||||
| mm | 普通功率RP | 普通高密功率HD | 高功率HP | 超高功率UHP |
| 250 | 7000-10000 | 8000-12000 | 8000-13000 | 一 |
| 300 | 10000-13000 | 11000-16000 | 13000-17400 | 15000-22000 |
| 350 | 13500-18000 | 15000-22000 | 17400-24000 | 20000-30000 |
| 400 | 18000-23500 | 20000-28000 | 21000-31000 | 25000-40000 |
| 450 | 22000-27000 | 24000-34000 | 25000-40000 | 32000-45000 |
| 500 | 25000-32000 | 28000-42000 | 30000-48000 | 38000-55000 |
| 550 | 28000-34000 | 31000-48000 | 34000-53000 | 45000-65000 |
| 600 | 30000-36000 | 34000-54000 | 38000-58000 | 50000-75000 |
| 650 | 32000-39000 | 41000-65000 | 60000-85000 | |
| 700 | 34000-42000 | 45000-72000 | 70000-120000 | |





We implement a strict and comprehensive quality control system throughout the entire production process – from raw material selection to final shipment.
| Solid raw material testing |
|---|
| Moisture Content |
| ASH |
| Volatile Matter |
| Sulphur Content |
| True Specific Gravity |
| Powder resistivity |
| Fixed Carbon |
| Particle Strength |
| Particle Size Distribution |
| Thermal Expansion Coeffcient |
| Scope of liquid raw material testing |
|---|
| Moisture content |
| Ash content |
| Volatile matter |
| Softening point |
| Coking value |
| Sulphur content |
| Toluene insolubles |
| Quinoline insoluble substance |
| Product testing |
|---|
| Resistivity |
| Bulk density |
| True specific gravity |
| Elastic modulus |
| Flexural Strength |
| Compressive strength |
| Thermal expansion coefficient |
Please do not stack the electrodes and connectors directly on the ground. They should be placed on wooden or iron frames to avoid electrode damage or sticking to soil. For electrodes that are not in use temporarily, do not throw away the packaging to prevent dust and debris from falling onto the threads or electrode threaded holes.
Graphite electrodes should be stored neatly in the warehouse, and both sides of the electrode stack should be leveled to prevent slipping. The stacking height of electrodes should generally not exceed 2 meters, and it is best not to exceed 4 layers.
The stored graphite electrodes should be protected from rain and moisture. If there are damp electrodes, they should be dried before use to avoid cracking, falling off, and increasing oxidation consumption during steelmaking.
Do not store the electrode nipple near high temperatures to prevent the nipple bolt from melting due to excessive temperature
When loading electric furnace materials into the furnace, in order to reduce the impact of material collapse and falling on the electrodes, large blocks of material should be placed in the middle near the bottom of the furnace. At the same time, attention should be paid not to allow non-conductive objects such as lime to accumulate in large quantities directly below the electrode, affecting the electrification effect or damaging the electrode
Attention should be paid to the position of the furnace cover. The furnace cover is skewed, and when the electrodes rise or fall, they will rub against the furnace cover, causing electrode damage and scraping
Electrodes should be used vertically to avoid tilting operations
Avoid using electrodes to add carbon to the molten steel to prevent electrode performance degradation
The sealing of the furnace cover should be good to reduce the amount of air entering, and appropriate use of combustion nozzles and oxygen should be made to reduce oxidation consumption at high temperatures
For electric furnaces with high vibration, the method of using pins can also be used to prevent loosening and trip
There are two types of tapered threads: one inch three buckles and one inch four buckles. When using, attention should be paid to the number of thread teeth on the lifting tool, and the number of thread teeth on the joint should match the number of thread teeth on the electrode hole
Due to the differences in raw materials and manufacturing processes used by various manufacturers, there are certain differences in the physical and chemical properties of electrodes and nipples. Therefore, in general, it is not allowed to exchange nipples and electrodes produced by different manufacturers for use
When connecting electrodes, if loose nipple bolts are found, they must be replaced or supplemented before connection and use
After electrode connection, if any gaps are found, the cause must be identified and eliminated before use